General Disclaimer: (HV) (DC) injury or death hazard, use at your own risk, may void warranty. |
Difference between revisions of "Prius PHEV Schematics"
(→Automatic Charge - PHEV Drive Mode Change: finished missed changes) |
(→Automatic Charge - PHEV Drive Mode Change: coil 5, better logic) |
||
| Line 59: | Line 59: | ||
Pair of DPDT or 4PDT, DPDT, and SPST (40+ Amps, 12v coils) | Pair of DPDT or 4PDT, DPDT, and SPST (40+ Amps, 12v coils) | ||
(+)[Grid](-) | (+)[Grid](-) | ||
| − | | | + | | coil 5 | (ac rated) |
| |====|======================================| | | |====|======================================| | ||
| | | | | | | | | | ||
| Line 86: | Line 86: | ||
|(+) (-)| |(-) (+)| | |(+) (-)| |(-) (+)| | ||
[PFC Input] [PFC Output] | [PFC Input] [PFC Output] | ||
| − | '''''Can we get a four poll tripple throw 40A, 60A, or 120A Contactor or Drum Switch?''''' | + | '''coils''' '''''Can we get a four poll tripple throw 40A, 60A, or 120A Contactor or Drum Switch?''''' |
| + | '''12345''' | ||
| + | Charge Mode | ||
| + | 00000 - Grid -> PbA, (PFC V set PbA ''default'') | ||
| + | ////0 - 110v AC Present (DC immune) coil 01&02&03&04&RLx interlock. (Set PFC Current < 15A) | ||
| + | ////0 - 220v AC Present (DC immune) coil 01&02&03&04&RLx interlock. (Leave PFC Current Full) | ||
| − | + | Power up sequence '''Key On''' | |
| − | + | 00001 - open coil 05 (NC), ac interlock | |
| − | + | 01001 - coil 02 Output -> NiMH, PFC V set NiMH low | |
| − | + | 11001 - coil 01 Input -> PbA | |
| − | + | CAN-View "PHEV" Mode, Relay RL4^ | |
| − | + | 11011 - Close coil 04 (NO), Connect PbA (-)neg leg (PFC On) | |
| − | + | CAN-View ?RL2^? (SOC/CCL Driven) | |
| − | + | 11011 - PFC V set NiMH high | |
| − | + | Power down sequence '''Key Off''' | |
| − | + | 11011 - Key On, and PHEV run state | |
| − | + | 11001 - Open coil 04 (NO), Disconnect PbA (-)neg leg (PFC Off) | |
| − | + | 01001 - coil 01 Input -> Grid | |
| − | + | 00001 - coil 02 Output -> PbA, PFC V Set PbA | |
| − | + | 00000 - close coil 05 (NC), ac interlock | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | + | CAN-View ?RL3^? (Enter Regen Mode) | |
| − | + | 1 - ''only while grid interlock is active'' | |
| − | + | 11011 - Key On, and PHEV run state | |
| − | + | Do Power down sequence '''Emulate Key Off''' less last state | |
| − | + | 11001 - Open coil 04 (NO), Disconnect PbA (-)neg leg (PFC Off) | |
| − | + | 01001 - coil 01 Input -> Grid | |
| − | + | 00001 - coil 02 Output -> PbA, PFC V Set PbA | |
| − | + | 00101 - coil 03 NiMH(Regen) -> Grid Input (PFC On) | |
| − | + | CAN-View ?RL3v? (Exit Regen Mode) | |
| − | + | 00101 - Key On, and PHEV regen state | |
| − | + | 00001 - coil 03 Grid -> Grid Input (PFC Off) | |
| − | + | 01001 - coil 02 Output -> NiMH, PFC V Set NiMH low | |
| − | + | 11001 - coil 01 Input -> PbA | |
| − | + | 11011 - Close coil 04 (NO), Connect PbA (-)neg leg (PFC On) | |
| − | ''(One could manually enter | + | |
| − | ''(Shut off PFC | + | ''Forced PbA Charge Mode'' |
| − | --[[User:Rjf|Rjf]] 04: | + | ''(One could manually enter forced PbA charge mode by safely enguaging stationary regen '''?RL3^?)'' |
| + | ''Further, External Charging by:'' | ||
| + | ''(Shut off PFC, hyjack PFC output via Andersons, V tune (?independent?) and charge)'' | ||
| + | --[[User:Rjf|Rjf]] 04:34, 14 June 2006 (CDT) | ||
====Enhanced Regen==== | ====Enhanced Regen==== | ||
Revision as of 09:34, 14 June 2006
This is where you will find schematics, PCB layout, and parts lists for various Prius PHEV conversions.
Original CalCars Method
Further development of the PriusPlus or Prius PHEV#Original CalCars Method has been postponed to persue the Prius PHEV#Hybrid-Pack Method so the original schematics can be found at Prius PHEV Schematics-CalCars
Hybrid-Pack Method
There is no longer a need for the Battery Tap Emulator.
The HV interface with the original battery is made after the HAL sensor.
View with fixed-width fonts
|======[? (-) for Genset Mode ?]
|
=(-)=[=#=OEM_Contactor=#=]===[|]==#========(-)
HAL | [_OEM_Battery_]
To HSD SENSOR | |===(+)
| |
=(+)=[=#=OEM_Contactor=#=]========|====|
| |
|====| |
| |
( # interconnect ) (+) (-)
( = & | 6 guage wire ) [_PHEV_Battery_]
Contactor Based
No new Schematics for these methods yet...
PFC Based
No new Schematics for these methods yet, Only ASCII Art...
Manual Anderson Quick Mode Change.
View with fixed-width fonts
Manual Anderson Quick Mode Change.
( 6 red, 6 black )
_______________ _ _____________________
In PFC AC(+) \ / (+) 110/220AC CHG |
_____PFC_AC(-)_/_\_(-)____________ CHG______
Out PFC DC(+) \ / (+) PbA (PHEV) CHG PHEV |
_____PFC_DC(-)_/_\_(-)________________ PHEV_____
/ (+) NiMH (OEM) PHEV RGN |
_ _ _ _ _ _ _ _ _\_(-)____________ _ _ _____RGN |
/ (+) PbA (PHEV) RGN |
_ _ _ _ _ _ _ _ _\_(-)____________ _ _ _ _ _____|
_ ________________
"Special Mode" / (+) HSD (? HAL sensor ?)
Wayland at the _\_(-)____________
track charging / (+) DC Output (! NEDRA !)
Genset Mode ?? _\_(-)____________
--Rjf 00:40, 26 May 2006
Automatic Charge - PHEV Drive Mode Change
View with fixed-width fonts This has not yet been validated for proper opperation
Automatic [ Charge - PHEV Drive - Regen ] Mode Change
Pair of DPDT or 4PDT, DPDT, and SPST (40+ Amps, 12v coils)
(+)[Grid](-)
| coil 5 | (ac rated)
| |====|======================================|
| | | |
| | | |==================================|========|
__|___|____|___|__ | |
! # # # # ! | |
! \ , %%%% \ , ! coil 03 only while RL4=1 | |
! \ coil \ ! | |
!___#___03___#___! | |
| | | |
(+) (-) (+)[PbA](-) (-)[NiMH](+)[NiMH](-)Regen Mode?
(no dc|ac inter|lock) | | | | Inverter side of OEM contactor
| | | | | |
| | | | | |
| |====|========#=======|==========|====| |
| | | | | | |
| | | |=======| #======| | | |
| | | | __|____|__ | | | |
| | | | | # ,, # ! | | | |
__|___|____|___|__ ! ---- ! __|___|____|___|__
! # # # # ! ! %%%% ! ! # # # # !
! \ , %%%% \ , ! ! coil ! ! \ , %%%% \ , !
! \ coil \ ! !___04___! ! \ coil \ !
!___#___01___#___! !___#___02___#___!
| | | |
|(+) (-)| |(-) (+)|
[PFC Input] [PFC Output]
coils Can we get a four poll tripple throw 40A, 60A, or 120A Contactor or Drum Switch?
12345
Charge Mode
00000 - Grid -> PbA, (PFC V set PbA default)
////0 - 110v AC Present (DC immune) coil 01&02&03&04&RLx interlock. (Set PFC Current < 15A)
////0 - 220v AC Present (DC immune) coil 01&02&03&04&RLx interlock. (Leave PFC Current Full)
Power up sequence Key On
00001 - open coil 05 (NC), ac interlock
01001 - coil 02 Output -> NiMH, PFC V set NiMH low
11001 - coil 01 Input -> PbA
CAN-View "PHEV" Mode, Relay RL4^
11011 - Close coil 04 (NO), Connect PbA (-)neg leg (PFC On)
CAN-View ?RL2^? (SOC/CCL Driven)
11011 - PFC V set NiMH high
Power down sequence Key Off
11011 - Key On, and PHEV run state
11001 - Open coil 04 (NO), Disconnect PbA (-)neg leg (PFC Off)
01001 - coil 01 Input -> Grid
00001 - coil 02 Output -> PbA, PFC V Set PbA
00000 - close coil 05 (NC), ac interlock
CAN-View ?RL3^? (Enter Regen Mode)
1 - only while grid interlock is active
11011 - Key On, and PHEV run state
Do Power down sequence Emulate Key Off less last state
11001 - Open coil 04 (NO), Disconnect PbA (-)neg leg (PFC Off)
01001 - coil 01 Input -> Grid
00001 - coil 02 Output -> PbA, PFC V Set PbA
00101 - coil 03 NiMH(Regen) -> Grid Input (PFC On)
CAN-View ?RL3v? (Exit Regen Mode)
00101 - Key On, and PHEV regen state
00001 - coil 03 Grid -> Grid Input (PFC Off)
01001 - coil 02 Output -> NiMH, PFC V Set NiMH low
11001 - coil 01 Input -> PbA
11011 - Close coil 04 (NO), Connect PbA (-)neg leg (PFC On)
Forced PbA Charge Mode
(One could manually enter forced PbA charge mode by safely enguaging stationary regen ?RL3^?)
Further, External Charging by:
(Shut off PFC, hyjack PFC output via Andersons, V tune (?independent?) and charge)
--Rjf 04:34, 14 June 2006 (CDT)
Enhanced Regen
Regen may need to transfer power through the OEM HAL sensor in order to:
- Avoid Negative State Of Charge Drift which may not work like +Drift.
- Allow current to be counted instantaneously and thus recover from or avoid CCL.
- Allow for the use of the Prius as a DC Genset if PFC sources NiMH pack.
Potential Enhanced Regen methods
- Use the PFC as is, switch Input/Output and change voltage setpoint.
- Modify the PFC so it can move 2x amps in DC modes only.
- Use a PFC power stage.. so we can stuff 150 amps in any direction.
- Use a Honking Big diode and a properly sized PbA Pack.
- Use a contactor and a diode and a properly sized PbA Pack.