General Disclaimer: (HV) (DC) injury or death hazard, use at your own risk, may void warranty. |
Difference between revisions of "Prius PHEV Schematics"
(LV Schematics.) |
(→PFC Based: Added simplified relay layout (no regen)) |
||
| Line 195: | Line 195: | ||
* Use a Honking Big diode and a properly sized PbA Pack. | * Use a Honking Big diode and a properly sized PbA Pack. | ||
* Use a contactor and a diode and a properly sized PbA Pack. | * Use a contactor and a diode and a properly sized PbA Pack. | ||
| + | |||
| + | |||
| + | ====Automatic Charge - PHEV Drive Mode Change (No Regen)==== | ||
| + | ''View with fixed-width fonts'' <font color=red>'''This has not yet been validated for proper opperation'''</font> | ||
| + | '''Automatic [ Charge - PHEV Drive ] Mode Change, HV & LV Layout''' | ||
| + | coil 01 is a pair of DPDT or a single 4PDT | ||
| + | coil 02 is a SPST (Rated 40+ Amps for DC MAKE/BREAK) | ||
| + | * Ignition energizes mode change (unless PFC is running from grid) | ||
| + | * CAN-View RL4 (OEM/PHEV Mode) energizes Coil 02 powering up PFC (DC MAKE) | ||
| + | * Once PFC is running mode change is energized by both ignition and PFC RegBus | ||
| + | ** Ignition off results in CAN-View RL4 releasing powering down PFC (DC BREAK) | ||
| + | ** Mode change can only return to grid once PFC RegBus goes offline | ||
| + | |||
| + | (+)[Grid](-) (+)[PbA](-) (-)[NiMH](+) | ||
| + | | | | | | | | ||
| + | | |====|========#=======|==========|====| | | ||
| + | | | | | | | | | ||
| + | | | | |=======| #======| | | | | ||
| + | | | | | __|____|__ | | | | | ||
| + | | | | | | # ,, # ! | | | | | ||
| + | __|___|____|___|__ ! ---- ! __|___|____|___|__ | ||
| + | ! # # # # ! ! %%%% ! ! # # # # ! | ||
| + | ! \ , %%%% \ , ! ! coil ! ! \ , %%%% \ , ! | ||
| + | ! \ coil \ ! !___02___! ! \ coil \ ! | ||
| + | !___#___01___#___! !___#___01___#___! | ||
| + | | | \ / | | | ||
| + | |(+) (-)| \ / |(-) (+)| ( +5v from ) | ||
| + | [PFC Input] \ / [PFC Output] ( PFC RegBus ) | ||
| + | \<===#===>/ | | | ||
| + | | | | (Ign +12v)---< | ||
| + | |=====| |=====#==========|====================| | | | | ||
| + | | __|____|__ | | | | | | | ||
| + | | | # ,, # ! | (coil / 01) |========| | | | | |=====| | ||
| + | | ! ---- ! | ______|________|__ __|____|__ | | __|____|__ | | ||
| + | | g===%%%%====| | ! # # # # ! | # ,, # ! | | | #____# ! | | ||
| + | | ! NO ! | |====%\ ,%%%%%%\ ,%==g ! ---- ! | | ! .... ! | | ||
| + | | !________! | ! \ \ ! |====%%%%=====#=|=====%%%%====| | | ||
| + | | | !___#________#___! | ! NO ! | ! NC ! | | | ||
| + | | | | | | !________! | !________! | | | ||
| + | |===(Bat +12)==|========#========# |===============#=============| | | ||
| + | | | | | ||
| + | ^ |========================================================| | ||
| + | --[[User:Rjf|Rjf]] 06:51, 2 September 2006 (CDT) | ||
[[Category:PHEV]] | [[Category:PHEV]] | ||
[[Category:Prius]] | [[Category:Prius]] | ||
[[Category:Prius PHEV]] | [[Category:Prius PHEV]] | ||
Revision as of 11:51, 2 September 2006
This is where you will find schematics, PCB layout, and parts lists for various Prius PHEV conversions.
Original CalCars Method
Further development of the PriusPlus or Prius PHEV#Original CalCars Method has been postponed to persue the Prius PHEV#Hybrid-Pack Method so the original schematics can be found at Prius PHEV Schematics-CalCars
Hybrid-Pack Method
There is no longer a need for the Battery Tap Emulator.
The HV interface with the original battery is made after the HAL sensor.
View with fixed-width fonts
|======[? (-) for Genset Mode ?]
|
=(-)=[=#=OEM_Contactor=#=]===[|]==#========(-)
HAL | [_OEM_Battery_]
To HSD SENSOR | |===(+)
| |
=(+)=[=#=OEM_Contactor=#=]========|====|
| |
|====| |
| |
( # interconnect ) (+) (-)
( = & | 6 guage wire ) [_PHEV_Battery_]
Contactor Based
No new Schematics for these methods yet...
PFC Based
No new Schematics for these methods yet, Only ASCII Art...
Manual Anderson Quick Mode Change.
View with fixed-width fonts
Manual Anderson Quick Mode Change.
( 6 red, 6 black )
_______________ _ _____________________
In PFC AC(+) \ / (+) 110/220AC CHG |
_____PFC_AC(-)_/_\_(-)____________ CHG______
Out PFC DC(+) \ / (+) PbA (PHEV) CHG PHEV |
_____PFC_DC(-)_/_\_(-)________________ PHEV_____
/ (+) NiMH (OEM) PHEV RGN |
_ _ _ _ _ _ _ _ _\_(-)____________ _ _ _____RGN |
/ (+) PbA (PHEV) RGN |
_ _ _ _ _ _ _ _ _\_(-)____________ _ _ _ _ _____|
_ ________________
"Special Mode" / (+) HSD (? HAL sensor ?)
Wayland at the _\_(-)____________
track charging / (+) DC Output (! NEDRA !)
Genset Mode ?? _\_(-)____________
--Rjf 00:40, 26 May 2006
Automatic Charge - PHEV Drive Mode Change
View with fixed-width fonts This has not yet been validated for proper opperation
Automatic [ Charge - PHEV Drive - Regen ] Mode Change, HV Layout
Pair of DPDT or 4PDT, DPDT, and SPST (40+ Amps, 12v coils)
(+)[Grid](-) Inputs --> State|Machine --> Outputs
__|________|__ +12v-|->(CAN RL3, NO, RGN )-->|-->(Execute Regen mode Procedure below)
! |coil 05 | ! Key |->(CAN RL2, NO, SOC )-->|-->(PFV V set NiMH high)
! |AC rated| ! |->(CAN RL4, NO, PHEV)-->|-->(coil 04)
!_|________|_! |-NC->(Key On, +12v, Brown)-->|-->(Interlock, coil 01 & 02, PFC V set NiMH low)
| | | |-NC----------->|-->(Open OEM HV+ Contactor ground control, Black)
(|AC sense|)---|-------------|----110vac---->|-->(PFC Current <15Amps)
| |
| |====|======================================|
| | | |
| | | |==================================|========|
__|___|____|___|__ | |
! # # # # ! | |
! \ , %%%% \ , ! | |
! \ coil \ ! (+)[PbA](-) (-)[NiMH](+)[NiMH](-)Regen Mode?
!___#___03___#___! | | | | Inverter side of OEM contactor
| | | | | |
| |====|========#=======|==========|====| |
| | | | | | |
| | | |=======| #======| | | |
| | | | __|____|__ | | | |
| | | | | # ,, # ! | | | |
__|___|____|___|__ ! ---- ! __|___|____|___|__
! # # # # ! ! %%%% ! ! # # # # !
! \ , %%%% \ , ! ! coil ! ! \ , %%%% \ , !
! \ coil \ ! !___04___! ! \ coil \ !
!___#___01___#___! !___#___02___#___!
| | | |
|(+) (-)| |(-) (+)|
[PFC Input] [PFC Output]
--Rjf 15:49, 14 June 2006 (CDT)
This has not yet been validated for proper opperation
coils Can we get a four poll tripple throw 40A, 60A, or 120A Contactor or Drum Switch?
12345
----- Charge Mode
00000 - Grid -> PbA, (PFC V set PbA default)
////0 - 110v AC Present (DC immune) coil 01-04, Key On, and RLx interlock. (Set PFC Current < 15A)
////0 - 220v AC Present (DC immune) coil 01-04, Key On, and RLx interlock. (Leave PFC Current Full)
- Key On Interlock opens a NC relay which grounds the (+)pos OEM Contactor.
- Run Interlock opens a NC relay which would otherwise go (+12) upon Key On.
- Open a NC relay which provides coil 01-04 & CAN RLx grounds, disabling all.
----- Power up sequence Key On
00000 - Key Off, ready to but not charging state
00001 - open coil 05 (NC), ac interlock
01001 - coil 02 Output -> NiMH, PFC V set NiMH low
11001 - coil 01 Input -> PbA
CAN-View "PHEV" Mode, Relay RL4^
11011 - Close coil 04 (NO), Connect PbA (-)neg leg (PFC On)
CAN-View ?RL2^? (SOC/CCL Driven)
11011 - PFC V set NiMH high
----- Power down sequence Key Off
11011 - Key On, and PHEV run state
11001 - Open coil 04 (NO), Disconnect PbA (-)neg leg (PFC Off)
01001 - coil 01 Input -> Grid
00001 - coil 02 Output -> PbA, PFC V Set PbA
00000 - close coil 05 (NC), ac interlock
----- CAN-View ?RL3^? (Enter Regen Mode)
1 - only while grid interlock is active
11011 - Key On, and PHEV run state
Do Power down sequence Emulate Key Off less last state
11001 - Open coil 04 (NO), Disconnect PbA (-)neg leg (PFC Off)
01001 - coil 01 Input -> Grid
00001 - coil 02 Output -> PbA, PFC V Set PbA
00101 - coil 03 NiMH(Regen) -> Grid Input (PFC On)
----- CAN-View ?RL3v? (Exit Regen Mode)
00101 - Key On, and PHEV regen state
00001 - coil 03 Grid -> Grid Input (PFC Off)
01001 - coil 02 Output -> NiMH, PFC V Set NiMH low
11001 - coil 01 Input -> PbA
11011 - Close coil 04 (NO), Connect PbA (-)neg leg (PFC On)
----- Other Notes
01001 - coil 02 & 01 states may be safe to combined
11001 - coil 01 & 02 states may be safe to combined
Forced PbA Charge Mode
(One could manually enter forced PbA charge mode by safely enguaging stationary regen ?RL3^?)
Further, External Charging by:
(Shut off PFC, hyjack PFC output via Andersons, V tune (?independent?) and charge)
--Rjf 15:49, 14 June 2006 (CDT)
View with fixed-width fonts This has not yet been validated for proper opperation
Automatic [ Charge - PHEV Drive - Regen ] Mode Change, LV Layout
(-)12v Acc(+)
| |
|======# |========|
| ____|____ ____|____
| ! # ! ! # !
(-)12v | ! \ ! ! \ ! (+)12v
When======#===#%,%\%#===| |====#%,%\%#=======(Brown)
AC Exists !_#___#_! | | !_#___#_! Key On
| | | | | |
MM-PFC=========| #====|===| | |
LowCurrent | | | |
if 110vac | |=========|===|
| |
OEM (-) Contactor | |
Leg (Black)========| | AC/Run Interlocks
...................................|.....................
(+)
|=========================|
|
| SPDT
#===NO==(Coil 01 & Coil 02), MM-PFC Vset Ni-Low=======(-(1) 12v)===#
| (Cap to Delay Opening and Closing) |
| |
| SPDT |
#===NO==CAN-RL4, Coil 04 (Pb->MM-PFC, Power On)=======(-(1) 12v)===#
| (No Cap, Opens and Closes Instantly) |
| |
| SPDT |
#===NO==CAN-RL2+3, (SOC Driver) MM-PFC Vset Ni-High===(-(1) 12v)===#
| |
| |
| |
| (-) 12v=!=NC======================!=============>==(-(1) 12v)=>=#
| !DPDT CAN-RL5+6, (Regen) !
#==========!=NO======================!=Coil 03===(-) 12v
( Remove (-(1) 12v) Coil 04 Drops Immediatly )
( Coil 01&02 Delayed )
( Coil 03 Delayed More )
( Adding (-(1) 12v) Coil 03 Drops Immediatly )
( Coil 01&02 Delayed )
( Coil 04 Delayed More )
--Rjf 00:24, 22 June 2006 (CDT)
Enhanced Regen
Regen may need to transfer power through the OEM HAL sensor in order to:
- Avoid Negative State Of Charge Drift which may not work like +Drift.
- Allow current to be counted instantaneously and thus recover from or avoid CCL.
- Allow for the use of the Prius as a DC Genset if PFC sources NiMH pack.
Potential Enhanced Regen methods
- Use the PFC as is, switch Input/Output and change voltage setpoint.
- Modify the PFC so it can move 2x amps in DC modes only.
- Use a PFC power stage.. so we can stuff 150 amps in any direction.
- Use a Honking Big diode and a properly sized PbA Pack.
- Use a contactor and a diode and a properly sized PbA Pack.
Automatic Charge - PHEV Drive Mode Change (No Regen)
View with fixed-width fonts This has not yet been validated for proper opperation
Automatic [ Charge - PHEV Drive ] Mode Change, HV & LV Layout
coil 01 is a pair of DPDT or a single 4PDT
coil 02 is a SPST (Rated 40+ Amps for DC MAKE/BREAK)
* Ignition energizes mode change (unless PFC is running from grid)
* CAN-View RL4 (OEM/PHEV Mode) energizes Coil 02 powering up PFC (DC MAKE)
* Once PFC is running mode change is energized by both ignition and PFC RegBus
** Ignition off results in CAN-View RL4 releasing powering down PFC (DC BREAK)
** Mode change can only return to grid once PFC RegBus goes offline
(+)[Grid](-) (+)[PbA](-) (-)[NiMH](+)
| | | | | |
| |====|========#=======|==========|====| |
| | | | | | |
| | | |=======| #======| | | |
| | | | __|____|__ | | | |
| | | | | # ,, # ! | | | |
__|___|____|___|__ ! ---- ! __|___|____|___|__
! # # # # ! ! %%%% ! ! # # # # !
! \ , %%%% \ , ! ! coil ! ! \ , %%%% \ , !
! \ coil \ ! !___02___! ! \ coil \ !
!___#___01___#___! !___#___01___#___!
| | \ / | |
|(+) (-)| \ / |(-) (+)| ( +5v from )
[PFC Input] \ / [PFC Output] ( PFC RegBus )
\<===#===>/ | |
| | | (Ign +12v)---<
|=====| |=====#==========|====================| | | |
| __|____|__ | | | | | |
| | # ,, # ! | (coil / 01) |========| | | | | |=====|
| ! ---- ! | ______|________|__ __|____|__ | | __|____|__ |
| g===%%%%====| | ! # # # # ! | # ,, # ! | | | #____# ! |
| ! NO ! | |====%\ ,%%%%%%\ ,%==g ! ---- ! | | ! .... ! |
| !________! | ! \ \ ! |====%%%%=====#=|=====%%%%====| |
| | !___#________#___! | ! NO ! | ! NC ! | |
| | | | | !________! | !________! | |
|===(Bat +12)==|========#========# |===============#=============| |
| | |
^ |========================================================|
--Rjf 06:51, 2 September 2006 (CDT)