General Disclaimer: (HV) (DC) injury or death hazard, use at your own risk, may void warranty. |
Difference between revisions of "Prius PHEV Schematics"
(→Automatic Charge - PHEV Drive Mode Change: finished missed changes) |
(→Automatic Charge - PHEV Drive Mode Change: coil 5, better logic) |
||
Line 59: | Line 59: | ||
Pair of DPDT or 4PDT, DPDT, and SPST (40+ Amps, 12v coils) | Pair of DPDT or 4PDT, DPDT, and SPST (40+ Amps, 12v coils) | ||
(+)[Grid](-) | (+)[Grid](-) | ||
− | | | + | | coil 5 | (ac rated) |
| |====|======================================| | | |====|======================================| | ||
| | | | | | | | | | ||
Line 86: | Line 86: | ||
|(+) (-)| |(-) (+)| | |(+) (-)| |(-) (+)| | ||
[PFC Input] [PFC Output] | [PFC Input] [PFC Output] | ||
− | '''''Can we get a four poll tripple throw 40A, 60A, or 120A Contactor or Drum Switch?''''' | + | '''coils''' '''''Can we get a four poll tripple throw 40A, 60A, or 120A Contactor or Drum Switch?''''' |
+ | '''12345''' | ||
+ | Charge Mode | ||
+ | 00000 - Grid -> PbA, (PFC V set PbA ''default'') | ||
+ | ////0 - 110v AC Present (DC immune) coil 01&02&03&04&RLx interlock. (Set PFC Current < 15A) | ||
+ | ////0 - 220v AC Present (DC immune) coil 01&02&03&04&RLx interlock. (Leave PFC Current Full) | ||
− | + | Power up sequence '''Key On''' | |
− | + | 00001 - open coil 05 (NC), ac interlock | |
− | + | 01001 - coil 02 Output -> NiMH, PFC V set NiMH low | |
− | + | 11001 - coil 01 Input -> PbA | |
− | + | CAN-View "PHEV" Mode, Relay RL4^ | |
− | + | 11011 - Close coil 04 (NO), Connect PbA (-)neg leg (PFC On) | |
− | + | CAN-View ?RL2^? (SOC/CCL Driven) | |
− | + | 11011 - PFC V set NiMH high | |
− | + | Power down sequence '''Key Off''' | |
− | + | 11011 - Key On, and PHEV run state | |
− | + | 11001 - Open coil 04 (NO), Disconnect PbA (-)neg leg (PFC Off) | |
− | + | 01001 - coil 01 Input -> Grid | |
− | + | 00001 - coil 02 Output -> PbA, PFC V Set PbA | |
− | + | 00000 - close coil 05 (NC), ac interlock | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | CAN-View ?RL3^? (Enter Regen Mode) | |
− | + | 1 - ''only while grid interlock is active'' | |
− | + | 11011 - Key On, and PHEV run state | |
− | + | Do Power down sequence '''Emulate Key Off''' less last state | |
− | + | 11001 - Open coil 04 (NO), Disconnect PbA (-)neg leg (PFC Off) | |
− | + | 01001 - coil 01 Input -> Grid | |
− | + | 00001 - coil 02 Output -> PbA, PFC V Set PbA | |
− | + | 00101 - coil 03 NiMH(Regen) -> Grid Input (PFC On) | |
− | + | CAN-View ?RL3v? (Exit Regen Mode) | |
− | + | 00101 - Key On, and PHEV regen state | |
− | + | 00001 - coil 03 Grid -> Grid Input (PFC Off) | |
− | + | 01001 - coil 02 Output -> NiMH, PFC V Set NiMH low | |
− | + | 11001 - coil 01 Input -> PbA | |
− | + | 11011 - Close coil 04 (NO), Connect PbA (-)neg leg (PFC On) | |
− | ''(One could manually enter | + | |
− | ''(Shut off PFC | + | ''Forced PbA Charge Mode'' |
− | --[[User:Rjf|Rjf]] 04: | + | ''(One could manually enter forced PbA charge mode by safely enguaging stationary regen '''?RL3^?)'' |
+ | ''Further, External Charging by:'' | ||
+ | ''(Shut off PFC, hyjack PFC output via Andersons, V tune (?independent?) and charge)'' | ||
+ | --[[User:Rjf|Rjf]] 04:34, 14 June 2006 (CDT) | ||
====Enhanced Regen==== | ====Enhanced Regen==== |
Revision as of 09:34, 14 June 2006
This is where you will find schematics, PCB layout, and parts lists for various Prius PHEV conversions.
Original CalCars Method
Further development of the PriusPlus or Prius PHEV#Original CalCars Method has been postponed to persue the Prius PHEV#Hybrid-Pack Method so the original schematics can be found at Prius PHEV Schematics-CalCars
Hybrid-Pack Method
There is no longer a need for the Battery Tap Emulator.
The HV interface with the original battery is made after the HAL sensor.
View with fixed-width fonts |======[? (-) for Genset Mode ?] | =(-)=[=#=OEM_Contactor=#=]===[|]==#========(-) HAL | [_OEM_Battery_] To HSD SENSOR | |===(+) | | =(+)=[=#=OEM_Contactor=#=]========|====| | | |====| | | | ( # interconnect ) (+) (-) ( = & | 6 guage wire ) [_PHEV_Battery_]
Contactor Based
No new Schematics for these methods yet...
PFC Based
No new Schematics for these methods yet, Only ASCII Art...
Manual Anderson Quick Mode Change.
View with fixed-width fonts Manual Anderson Quick Mode Change. ( 6 red, 6 black ) _______________ _ _____________________ In PFC AC(+) \ / (+) 110/220AC CHG | _____PFC_AC(-)_/_\_(-)____________ CHG______ Out PFC DC(+) \ / (+) PbA (PHEV) CHG PHEV | _____PFC_DC(-)_/_\_(-)________________ PHEV_____ / (+) NiMH (OEM) PHEV RGN | _ _ _ _ _ _ _ _ _\_(-)____________ _ _ _____RGN | / (+) PbA (PHEV) RGN | _ _ _ _ _ _ _ _ _\_(-)____________ _ _ _ _ _____| _ ________________ "Special Mode" / (+) HSD (? HAL sensor ?) Wayland at the _\_(-)____________ track charging / (+) DC Output (! NEDRA !) Genset Mode ?? _\_(-)____________ --Rjf 00:40, 26 May 2006
Automatic Charge - PHEV Drive Mode Change
View with fixed-width fonts This has not yet been validated for proper opperation Automatic [ Charge - PHEV Drive - Regen ] Mode Change Pair of DPDT or 4PDT, DPDT, and SPST (40+ Amps, 12v coils) (+)[Grid](-) | coil 5 | (ac rated) | |====|======================================| | | | | | | | |==================================|========| __|___|____|___|__ | | ! # # # # ! | | ! \ , %%%% \ , ! coil 03 only while RL4=1 | | ! \ coil \ ! | | !___#___03___#___! | | | | | | (+) (-) (+)[PbA](-) (-)[NiMH](+)[NiMH](-)Regen Mode? (no dc|ac inter|lock) | | | | Inverter side of OEM contactor | | | | | | | | | | | | | |====|========#=======|==========|====| | | | | | | | | | | | |=======| #======| | | | | | | | __|____|__ | | | | | | | | | # ,, # ! | | | | __|___|____|___|__ ! ---- ! __|___|____|___|__ ! # # # # ! ! %%%% ! ! # # # # ! ! \ , %%%% \ , ! ! coil ! ! \ , %%%% \ , ! ! \ coil \ ! !___04___! ! \ coil \ ! !___#___01___#___! !___#___02___#___! | | | | |(+) (-)| |(-) (+)| [PFC Input] [PFC Output] coils Can we get a four poll tripple throw 40A, 60A, or 120A Contactor or Drum Switch? 12345 Charge Mode 00000 - Grid -> PbA, (PFC V set PbA default) ////0 - 110v AC Present (DC immune) coil 01&02&03&04&RLx interlock. (Set PFC Current < 15A) ////0 - 220v AC Present (DC immune) coil 01&02&03&04&RLx interlock. (Leave PFC Current Full) Power up sequence Key On 00001 - open coil 05 (NC), ac interlock 01001 - coil 02 Output -> NiMH, PFC V set NiMH low 11001 - coil 01 Input -> PbA CAN-View "PHEV" Mode, Relay RL4^ 11011 - Close coil 04 (NO), Connect PbA (-)neg leg (PFC On) CAN-View ?RL2^? (SOC/CCL Driven) 11011 - PFC V set NiMH high Power down sequence Key Off 11011 - Key On, and PHEV run state 11001 - Open coil 04 (NO), Disconnect PbA (-)neg leg (PFC Off) 01001 - coil 01 Input -> Grid 00001 - coil 02 Output -> PbA, PFC V Set PbA 00000 - close coil 05 (NC), ac interlock CAN-View ?RL3^? (Enter Regen Mode) 1 - only while grid interlock is active 11011 - Key On, and PHEV run state Do Power down sequence Emulate Key Off less last state 11001 - Open coil 04 (NO), Disconnect PbA (-)neg leg (PFC Off) 01001 - coil 01 Input -> Grid 00001 - coil 02 Output -> PbA, PFC V Set PbA 00101 - coil 03 NiMH(Regen) -> Grid Input (PFC On) CAN-View ?RL3v? (Exit Regen Mode) 00101 - Key On, and PHEV regen state 00001 - coil 03 Grid -> Grid Input (PFC Off) 01001 - coil 02 Output -> NiMH, PFC V Set NiMH low 11001 - coil 01 Input -> PbA 11011 - Close coil 04 (NO), Connect PbA (-)neg leg (PFC On) Forced PbA Charge Mode (One could manually enter forced PbA charge mode by safely enguaging stationary regen ?RL3^?) Further, External Charging by: (Shut off PFC, hyjack PFC output via Andersons, V tune (?independent?) and charge) --Rjf 04:34, 14 June 2006 (CDT)
Enhanced Regen
Regen may need to transfer power through the OEM HAL sensor in order to:
- Avoid Negative State Of Charge Drift which may not work like +Drift.
- Allow current to be counted instantaneously and thus recover from or avoid CCL.
- Allow for the use of the Prius as a DC Genset if PFC sources NiMH pack.
Potential Enhanced Regen methods
- Use the PFC as is, switch Input/Output and change voltage setpoint.
- Modify the PFC so it can move 2x amps in DC modes only.
- Use a PFC power stage.. so we can stuff 150 amps in any direction.
- Use a Honking Big diode and a properly sized PbA Pack.
- Use a contactor and a diode and a properly sized PbA Pack.