General Disclaimer: (HV) (DC) injury or death hazard, use at your own risk, may void warranty. |
Difference between revisions of "File:100 1442.JPG"
Jump to navigation
Jump to search
(OEM HV tie-in.) |
(enhanced description) |
||
Line 1: | Line 1: | ||
OEM HV tie-in. | OEM HV tie-in. | ||
+ | |||
+ | Top to bottom as they leave the case: | ||
+ | * HV Positive at OEM contactor | ||
+ | * HV Negetive at OEM contactor (outside the HAL sensor) | ||
+ | ** May be required for regen mode, as of yet untested. | ||
+ | * HV Negetive at new junction (inside the HAL sensor) | ||
+ | ** New short cable from contactor through HAL sensor<br>rejoins OEM cable and new PHEV cable. |
Latest revision as of 18:59, 26 June 2006
OEM HV tie-in.
Top to bottom as they leave the case:
- HV Positive at OEM contactor
- HV Negetive at OEM contactor (outside the HAL sensor)
- May be required for regen mode, as of yet untested.
- HV Negetive at new junction (inside the HAL sensor)
- New short cable from contactor through HAL sensor
rejoins OEM cable and new PHEV cable.
- New short cable from contactor through HAL sensor
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 18:52, 26 June 2006 | 2,580 × 1,720 (710 KB) | Rjf (talk | contribs) | OEM HV tie-in. |
You cannot overwrite this file.
File usage
The following 2 pages use this file: